The pilot light will ignite your water heater s burner and if it goes out there is nothing to heat the water.
Water heater thermostat burnt.
Cut out the overheated wire.
After opening it up we discovered the red wire on the bottom element was burning.
Your water heater will usually have directions on how to relight it.
Thoroughly clean the bare wire ends of any coating or corrosion to bright copper and crimp the wire ends together tightly insulating the resulting connection with heat shrink tubing.
It had bared the red off the wire about 6in along it and also burnt the plastic cover.
Water came from somewhere possibly upper head weld caused corrosion and arcing of contacts inside thermostat.
The lower thermostat melted i am not sure why just yet.
If this is beyond your expertise get an electrician to do it.
Hj az a shorted element depending on where it is shorted would either cause the water to overheat and trip the eco or trip the circuit breaker but not overload the thermostat or its connections.
Finding the source of the leak will tell you where fault lies.
The water heater is running 240 volt on 10 awg wire with a 30 amp breaker at the box which never tripped.
Thermostat burned up etcetera.
I have a 3 year old kenmore electric water heater.
Water heater smells like.
By the second day it was getting stronger and smelt like a burning smell coming from the water heater area.
When this happens the heating element will burn out prematurely after heating the water to excessive temperatures.
Using a continuity tester available from electrical supply houses place one test probe on each of the element terminals.
What causes burned wires on electric water heater thermostat.
The heating element could be grounding out which will result in the heating element staying on.
Remove the cover panel s from the front of the heater and then disconnect the wires from the heating element terminals.
You can see if the pilot light is out by removing the cover of the water heater and inspecting the light.
To test for a burned out element first turn off all electrical power to the water heater.
I need to go and buy a volt ohm meter to test the element.
To check it remove one wire from the element terminals and set a volt ohm meter to rx1.
Strip back the insulation the correct amount for an appropriate crimp connector.