Using the flexible gas hose connect the gas control valve on the water heater and the gas supply line.
Water heater vent hood sheet metal screws.
Measure a straight section of new galvanized vent pipe to rise as.
Attach the vent pipe to the draft hood using the sheet metal self tapping screws.
Do not use regular duct tape to secure or seal connections.
If the recommended vent pipe diameter is larger than the vent hood opening don t install a reducer.
Some building inspectors don t even allow aluminum tape on joints.
Some adjustments might be needed as long as the original size and shape are kept.
Only use the draft hood that is supplied with the water heater.
Check the installation manual for the recommended diameter vent pipe for your new heater.
Snap the new draft hood onto the water heater and secure it with sheet metal screws.
Residential size water heaters have usually 3 or 4 diameter draft hoods some accept both sizes.
Look to see if the draft hood over the vent hole is centered and if the legs are straight and secured by screws this may depend on the design of the pipe.
Draft hood and gas water heater vent pipe connections.
While installing the vent pipe over the draft hood you must secure the connection with the sheet metal screw.
Cut the pipe to the appropriate length with sheet metal shears.
On 2020 03 18 by mod cold single wall metal vents may not vent the water heater properly.
Water heater inspection draft hood.
Fasten the flue pipe and fittings together with sheet metal screws.
The size of the vent pipe must not be smaller than the draft hood and connection must be airtight to prevent the leak of the flue gases.
A draft hood must only be connected to an equal or larger sized vent pipe as allowed by code.
Make sure to have the vent pipe rise vertically at least 12 before installing the elbow.
Place furnace tape around the joints to ensure tight seals.
Use three screws per joint.
Check to see if the draft hood and water heated flue pipe connections are properly secured with sheet metal screws.
Even if you don t face a fire hazard a single wall vent might for some heaters be too cold and thus the heater might not vent properly in some climates locations.
Water heater draft hood s diameter depends on the size btu s of the appliance.
Seal joint at bottom of vent pipe increaser 4 inch vent pipe 3 inch draft hood when two vent pipes are made by different manufacturers they may not fit together.